Plate Heat Exchanger NORDIC Ba-32-60 1" 330kW
HVAC Plate Heat Exchanger for 60 plates NORDIC TEC Ba-32-60
- Plate Q'ty: 60 pcs.
- Connections: 1" BSP
- Heat Exchange Area: 1.92m²
60-plate heat exchanger, commonly employed in conjunction with heat pumps (both split and monoblock systems) , as well as larger heating boilers, heaters, and similar applications. The nominal power of the heat exchanger is 330 kW measured for high parameters. In case of any issues with selecting the heat exchanger, please contact us.
☑️ As an option - the possibility to purchase a Ba-32-60 heat exchanger with insulation and a mounting kit (wall-mounting set with rotary fittings)
✅ Instant availability & Free delivery in: FR, IT, ES, DE, PL, AT, SI, DK, NL, BE, CZ, LV, LT, EE
Reference: NT Ba-32-60
Condition New
Heat Exchanger Nordic Tec Ba-32-60 destinated for heat pumps or other heating solutions
Soldered 60-plate heat exchanger with 1-inch connections. This heat exchanger is commonly used with heat pumps (connecting monoblock pumps to heating systems).
4x 1", 60 plates
Technical details:
- Stainless Steel S316L, brazed with 99,9% Cu
- Connections: 4x 1", BSP
- Working Pressure - <30 bar
- Test Pressure - 45-60 bar
- Max. temperature +230°C
- Flowrate - 12 m³/h
Total Active Plate Area / Heat Exchange Surface of PHE Ba-32-60 - 1.920 m²
The heat exchanger Ba-32-60 has a surface 1.92 square meter, which makes this a good solution for:
- plate heat exchanger for connecting the central heating installations (for example in a sealed system) with a coal/wood boiler of about 60-70 kW
- the paralel installation as above - using another boilers or burners, for example fueled with eco-pea, biomass, pellet (up to 60 - 70kW)
- plate heat exchanger connecting heat pumps - monoblock / split - with the house heating system, wiht a heat pump of 8 - 13 kW of nominal power,
depending on the powering temperature - connecting air heaters (for example Volcano type) to the heat source, even if they are filled with glycol
- industrial application, like refrigeration & cooling system
- so called "passive-cooling" using the heat pump installation for cooling houses in Summer
- all the installations which are separated from the main part & and have glycol inside
Dimensions:
(A) - 286 mm
(B) - 116 mm
(F) - 151 mm
(C) - 243 mm
(D) - 72 mm
Counter-current connection of the plate exchanger to the heating system (or cooling system) | Ba-32-60
We always connect the plate exchangers with 2 opposite directions of a liquid flow - i.e. in accordance with the counter current principle. All Nordic Tec plate exchangers are based on this principle, which means that only counter-courent connection ensures that they will get their full performance. In short, this principle boils down to the fact that the heating factors must flow in directions opposite to each other. When the device is connected without this rule, the exchanger will lose from 30 to even 50% of its possible performance, i.e. it will continue to work, but we will probably feel it in the form of an underheated home.
_________________________
You might be looking for a HE - plate heat exchanger for heat pumps, but you want to better match the model and review more items from our catalog before making a decision.
Check out our category grouping the most commonly used heat exchangers for heat pumps monoblock - using glycol/water circuits.
1151 Items
New
No reviews
You might also like