30-Plates Heat Exchanger with dimensions

Plate Heat Exchanger NORDIC Ba-32-30 1" 175kW

Plate Heat Exchanger NORDIC TEC Ba-32-30 1"

One of the most popular Brazed Plate Heat Exchanger models on the European market, with external threads 1". Optminal size of the plate heat exchanger for many domestic heating systems, cooperating both with smaller heat pumps and with conventional heat sources. Very good solutions for e.g. gas boilers.

  • Plate Q'ty: 30 pcs.
  • Connections: 1" BSP
  • Heat Exchange Area: 0.960m²

30-plate heat exchanger for domestic or industrial heating systems (central heating or domestic hot water) or cooling systems. Versatile in terms of compatibility with various heat sources (heat pumps, fireplaces, solid fuel boilers, condensing boilers - gas, and others). It can work with both water and glycol (glycol solution).

Reference: NT Ba-32-30
Condition New
Accessories for PHE
  • Exchanger only (without accesories)
  • with Wall-Mounting+Fittings
  • With Thermal Insulation
  • Full Set (with Insulation&Wall-mounting with Fittings)
On stock
€164.99
VAT included

 

Heat Exchanger with 30 plates - Nordic Tec Ba-32-30 - 4x 1 inch





Technical details - Heat Exchanger with 30 plates:

  • Stainless Steel S316L, brazed with Cu
  • Connections: 4x 1", BSP
  • Working Pressure - <30 bar

The heat exchanger Ba-32-30 should not operate with fluids requiring pressures higher than 30 bar, including R410, R32 and similar refrigerants, unless there is certainty that in the given system, pressures higher than 30 bar will not occur.

  • Test Pressure - 45-60 bar
  • Max. temperature +230°C
  • PHE Volume per 1 channel - 0.75 l
  • Flowrate - 12 m³/h



Plate Heat Exchanger Ba-32-30 - and its Heat Exchange Surface - 0.96 m²

heat trasfer surface Ba-32-30 phe by nordic tec

As we can see on the graph Ba-32-30 PHE with the surface of almost 1 m² of heat transfer area is one of 8 basic heat exchanger models gathered in series Ba-32. If for our application this plate surface seems to be too modest - we can use Ba-32-40 or Ba-32-50 etc, up to our needs. Every 10 plates of the PHE from this series means + 0,32m² of extra plate area.

Most common applications of a Plate Heat Exchanger Ba-32-30:

  • Installation with a fireplace as an additional heat source | Plate Heat Exchanger for a fireplace which can connect a open vented fireplace system with a sealed heating system
  • Central heating installations with boilers | Heat exchanger for connecting boiler to a CH system
  • Solar panels (collectors) | Plate heat exchanger for glycol solar systems
  • Industrial refrigeration | as a heat exchanger working with liquid to liquid refrigeration appplications
  • Central heating installations with heat pumps | mostly as a heat exchanger to separate a monoblock heat pump glycol circuit
  • Heating of warehouse halls using warm air heaters

Dimensions:

heat-exchanger-30-plates-dimensions

_______________________________________

Brazed Plate Heat Exchanger construction - Ba-32-30

A PHE is a flow device - that is, it only works when water flows through it or other medium that we have in the installation, e.g. glycol. It is not a tank because it does not accumulate water. This is an advantage, because it allows you to maintain a small size of the device.

In fact, it is a very simple design - it is a package of steel plates that are combined with each other, using the so-called vacuum soldering. It is a modern way to combine materials with a huge advantage over traditional welding. It takes place at a temperature of over 400 °C (although vacuum soldering can achieve temperatures of up to 900 °C) and takes place in specially created conditions without air.

What devices can the Ba-32-30 30-plate heat exchanger work with?

  • It can easily handle gas, pellet, coal, solid fuel, biomass boilers, and similar devices with a power output within the range of 30-35 kW, and in favorable conditions, even slightly larger ones.
  • Fireplaces or so-called water jacket stoves for central heating or domestic hot water - with a similar power output to the aforementioned heating boilers - that is 30-35 kW
  • Heat pumps - when connected to central heating or domestic hot water systems (in a water/glycol circuit) - with a heat pump power output of about 8 kW (high-temperature DHW system with radiators) or 5 kW (low-temperature DHW system with underfloor heating).
  • Numerous other applications, including refrigeration & cooling

What size facilities can the Nordic Tec Ba-32-30 heat exchanger heat?

The main factor in selecting such a device should be its proper adaptation to the requirements of the heat source, i.e., the heating device. However, in practice, the Ba-32-30 is capable of heating a building with an area of up to 300m² in an old building and even up to 400-450 m² in a new building, provided that the heat source is efficient enough.