Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW
Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW whole set
Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW on the wall hanged with a wall-mounting kit
Plate Heat Exchanger Ba-32-50 1" Nordic Tec with insulation box
Plate Heat Exchanger NORDIC TEC Ba-32-50 1" 285 kW with mounting kit and insulation
Plate Heat Exchanger NORDIC Ba-32-50 dimensions
Plate Heat Exchanger Ba-32-50 Nordic Tec with insulation box
Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW hanged on the wall
Wall-mounting service for Plate Heat Exchangers Ba-32-50
Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW
Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW whole set
Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW on the wall hanged with a wall-mounting kit
Plate Heat Exchanger Ba-32-50 1" Nordic Tec with insulation box
Plate Heat Exchanger NORDIC TEC Ba-32-50 1" 285 kW with mounting kit and insulation
Plate Heat Exchanger NORDIC Ba-32-50 dimensions
Plate Heat Exchanger Ba-32-50 Nordic Tec with insulation box
Plate Heat Exchanger NORDIC Ba-32-50 1" 285 kW hanged on the wall
Wall-mounting service for Plate Heat Exchangers Ba-32-50

Plate Heat Exchanger NORDIC Ba-32-50 1" 285kW

50-Plate Heat Exchanger NORDIC TEC Ba-32-50

Plate heat exchanger - brazed, with 50 plates - nominal power 285 kW (high parameter) per 1 inch

  • Connections: 1" BSP
  • Plate Q'ty: 50 pcs.
  • Heat Exchange Area: 1.600m²

☑️ Optionally, the possibility to purchase a Ba-32-50 heat exchanger with insulation and a mounting kit (wall-mounting with rotary fittings)
✅ Instant availability & Free delivery in: FR, IT, ES, DE, PL, AT, SI, DK, NL, BE, CZ, LV, EE, LT

Reference: NT Ba-32-50
Condition New
Accessories for PHE
  • Exchanger only (without accesories)
  • with Wall-Mounting+Fittings
  • With Thermal Insulation
  • Full Set (with Insulation&Wall-mounting with Fittings)
On stock
€239.99
VAT included

 

Heat exchanger for central heating systems for connecting heat pump units and heating boilers

Heat exchanger for central heating - Nordic Tec Ba-32-50,
Connections: 1", 50 plates


Heat Exchanger Ba-32-50 for HP monobloc 8 10 12 kW

Technical details:

  • Stainless Steel S316L, brazed with 99,9% Cu
  • Connections: 4x 1", BSP
  • Working Pressure - <30 bar
  • Test Pressure - 45-60 bar
  • Max. temperature +230°C
  • Flowrate - 12 m³/h

The device - Plate Heat Exchanger Ba-32-50 with 50 plates - can easily handle the operation of a gas boiler with a maximum capacity of up to 60 kW, while maintaining low supply temperatures (up to 50°C). For solid fuel boilers like eco-coal, pellet, or coal, if the set temperature is between 55-60°C, the heat exchanger's capacity can be even larger, for example, 65-70 kW.

The heat exchanger is also well-suited for use with a heat pump when connected to a heating system. In the case of a radiator-based system, it optimally handles heat pumps with capacities of around 10-12 kW. For systems relying solely on underfloor heating with low supply temperatures, smaller heat pumps with capacities of around 5-6 kW are more suitable.

The presence of glycol on the heat pump side does not pose a problem for the heat exchanger by Nordic Tec, that's only the question of the correct selection.



Ba-32-50 Plate Heat Exchanger - Heat Exchange Surface - 1.60 m²

Heat Transfer - Ba-32-50 heat exchanger for HP monobloc with glycol


Dimensions:
Connections location on the PHE for heat pumps - Ba-32-50 with 1
(A) -
286 mm
(B) -
116 mm
(F) -
127 mm
(C) -
243 mm
(D) -
72 mm


In DOWNLOAD section you get the data sheet of the unit.

____________________________

The most common use of the 50-plate Heat Exchanger Nordic TEC Ba-32-50:

  • Heat Exchanger for Fireplace installations with larger water jackets, with a power of at least several dozen kilo   
  • Plate Heat Exchanger for installations of central heating systems with heating boilers, e.g. with condensing boilers within 60 kW
  • Larger sets of solar panels (solar collector sets), with a larger surface
  • Cooperation with air heaters (e.g. Volcano) working on glycol or water, regardless of the type of power supply
  • Cooperation with a heat pump on water or glycol solution, both in the floor and radiators, both monobloc and split - a heat exchanger for connecting monoblock heat pumps (in case of correct sizing)
  • Passive cooling using a heat pump installation
  • Work in the food industry (pasteurization) - heating or cooling after the processus
  • Hot water heating bypassing the buffer
  • Industrial refrigeration

For this model, due to its weight (around 7.5 kg without media), we recommend using a mounting bracket with screws. This will ensure stability in operation over the years. The mounting bracket can be chosen as an optional accessory at the time of purchase, similar to insulation, which we recommend if the heat exchanger is not intended for cooling applications.

_________________________

You might be looking for a HE - plate heat exchanger for heat pumps monbock (or split), but you want to better match the model and check more PHE sets from our catalog before making a decision.
Check out our category which groups the most commonly used:

1129 Items
New
No reviews

You might also like

Customers who bought this product also bought:

Product added to wishlist
Cookie consent