Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW insulation
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW jacket
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW set
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW kit
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW mounting kit
Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW kit
Odpływ liniowy AZTEK 60cm
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW insulation
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW jacket
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW set
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW kit
Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW mounting kit
Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW kit
Odpływ liniowy AZTEK 60cm

Plate Heat Exchanger NORDIC Tec Ba-27-90 1 1/4" 500kW

90-Plate Heat Exchanger for Heat Pumps connecting NORDIC TEC Ba-27-90 5/4"

Plate Q'ty: 90 pcs.
Connections: 1 1/4" BSP
Heat Exchange Area: 2.430m²

Reference: EU-NT Ba-27-90
Condition New
Accessories for PHE
  • Exchanger only (without accesories)
  • with Wall-Mounting+Fittings
  • With Thermal Insulation
  • Full Set (with Insulation&Wall-mounting with Fittings)
On stock
€429.99
VAT included

 

Heat Exchanger - Nordic Tec Ba-27-90 4x 1 1/4", 90 plates





Technical details:

- Stainless Steel S316L, brazed with 99,9% Cu

- Connections: 4x 5/4", BSP

- Working Pressure - <30 bar

- Test Pressure - 45-60 bar

The working pressure refers to the maximum pressure at which the heat exchanger should operate under normal operating conditions. A value of 30 bar typically indicates that it is a liquid-to-liquid heat exchanger. It should not be used with high-pressure media such as refrigerants, which often operate at pressures higher than 30 bar.
On the other hand, the test pressure is the pressure applied briefly during acceptance tests of the heat exchanger. However, this pressure does not imply that the heat exchanger can operate continuously at such pressures.

- Max. temperature +230°C

- Flowrate - 12 m³/h

- Heat Exchange Surface - 2.430 m²


The most common applications of the Heat Exchanger Ba-27-90 5/4" - include:


Dimensions:
Heat Pump Plate Heat Exchanger Ba-27-80
(A) -
286 mm
(B) -
116 mm
(F) -
225 mm
(C) -
234 mm
(D) -
63 mm


In DOWNLOAD section you get the data sheet of the unit.