brazed plate heat exchanger ba-12-20 3/4 1/2
brazed plate heat exchanger ba-12-20 connections
brazed plate heat exchanger ba-12-20 3/4 1/2
brazed plate heat exchanger ba-12-20 connections

Plate Heat Exchanger NORDIC Ba-12-20 3/4"&1/2" 45kW

Heat Exchanger for heating or cooling applications - NORDIC TEC Ba-12-20 3/4 & 1/2

Plate Quantity: 20 pcs.
Connections: 2x 3/4" & 2x 1/2" BSP
Heat Exchange Surface: 0.24 m²

A 20-plate heat exchanger with 2 channels, each having connections of different diameters. One channel of the heat exchanger has 3/4" connections, while the other has 1/2" connections. It can be utilized in applications where there is a difference in mass flow rate in favor of one side.

☑️ Fast delivery to most European countries - just few days.
✅ Delivery is FREE in the following countries: FR, IT, AT, DE, NL, BE, ES, DK, PL, CZ, LT, LV, EE, SI

Reference: NT Ba-12-20 3/4&1/2"
Condition New
Accessories for PHE
  • Exchanger only (without accesories)
  • With Thermal Insulation
On stock
€64.99
VAT included

 

Brazed Plate Heat Exchanger - PHE for small cooling & heating systems

Small Brazed Plate Heat Exchanger Nordic Tec Ba-12-20 - 3/4 & 1/2", 20 plates



Brazed Plate Heat Exchanger for small glycol circuits

Technical details - Brazed Plate Heat Exchanger Ba-12-20 3/4 & 1/2":

  • BPHE plate material: Stainless Steel S316L, brazed with 99,9% Cu
  • Liquid Threads: 2x 3/4 & 2x 1/2"
  • Working Pressure - <10 bar
    Test Pressure - 20 bar
    As the pressures show - this is a brazed plate heat exchanger dedicated for work with liquid.

  • Max. temperature +230°C
  • Flowrate - 4 m³/h

- Heat Exchange Surface - BPHE Ba-12-20 : 0.240 m²

Brazed Plate Heat Exchanger for a sealed system Ba-12-20

The most common application of Plate Heat Exchanger Ba-12-20 with 20 plates

  • additional small heating circuits (additional room, additional radiators, etc.) | Small Plate Heat Exchanger for small heating circuits
  • an additional loop filled with glycol due to the frost risk | Brazed plate heat exchanger for small glycol circuits
  • connecting small apartments to the district heating network systems | Heat Exchanger for appartments powered by district heating
  • work with small water jackets / fireplaces with a power of 8 - 9 kW | Heat Exchanger for small water fireplaces to keep their work in an open vented system
    The exchanger due to too small size is not intended to support the entire central heating in a single-family building, but it can work in heating the small apartment.


Dimensions - Brazed Plate Heat Exchanger Ba-12-20 3/4 & 1/2":


PHE Plate Heat Exchanger - how big is such a device?


(A) -
191 mm
(B) -
73 mm
(F) -
52 mm
(C) -
154 mm
(D) -
40 mm

In our store you can find the above model also in a set with thermal insulation.
For this heat exchanger, we do not offer a mounting bracket, due to the unusual variation of connections that are smaller on one channel (1/2").



75 Items
New
No reviews

You might also like

Customers who bought this product also bought:

Product added to wishlist