Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285kW 5/4
Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285kW dimensions
plate he ba-27-50
Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285 kW
Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285
Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285kW 5/4
Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285kW dimensions
plate he ba-27-50
Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285 kW
Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285

Plate Heat Exchanger NORDIC Ba-27-50 1 1/4" 285kW

Plate Heat Exchanger with 50 plates and 1 1/4" threads NORDIC TEC Ba-27-50

Classic BPHE - Brazed Plate Heat Exchanger with 50 plates the connectors 1 1/4" by Nordic Tec

Plates Number: 50 pieces
Connections: 1 1/4" BSP
Heat Exchange Area: 1.350m²

Reference: NT Ba-27-50
Condition New
Accessories for PHE
  • Exchanger only (without accesories)
  • with Wall-Mounting+Fittings
  • With Thermal Insulation
  • Full Set (with Insulation&Wall-mounting with Fittings)
On stock
€244.99
VAT included

 

Heat Exchanger Nordic Tec Ba-27-50 - 4x 1 1/4", 50 plates

Nordic Tec Ba-27-50 heat exchanger full kit

Technical details:

- Stainless Steel S316L, brazed with 99,9% Cu

- Connections: 4x 5/4", BSP

- Working Pressure - <30 bar

- Test Pressure - 45-60 bar

- Max. temperature +230°C

- Flowrate - 12 m³/h

- Heat Exchange Surface - 1.350 m²



Dimensions:
Ba-27-50 heat exchanger Nordic Tec
(A) - 286 mm
(B) -
116 mm
(F) -
127 mm
(C) -
234 mm
(D) -
63 mm

What is the most common application for this heat exchanger - Ba-27-50?

The most commonly reported application for this heat exchanger (based on conversations with customers and distributors ) is its use in conjunction with heat pumps in radiator or mixed (radiator/underfloor heating ) systems. These systems achieve relatively high supply temperatures compared to typical heat pump heating . A notable advantage is the larger connection size , making this heat exchanger useful in situations where minimizing resistance is important, such as when the heat source is significantly distant from the heating system or when a more concentrated glycol solution is used . The second most common application is with traditional heat sources, typically coal or gas boilers.

_______________________

In DOWNLOAD section you get the data sheet of the unit.

_______________________

Check as well our other plate heat exchangers with threads 1 1/4". similar to this item:



48 Items
New
No reviews

You might also like

Customers who bought this product also bought:

Product added to wishlist