Plate Heat Exchanger NORDIC Tec Ba-16-40 1 inch 18 kW
brazed plate heat exchanger with 40 plates and 1 inch
Plate Heat Exchanger NORDIC Ba-16-40 viessman 24kW
Plate Heat Exchanger NORDIC Tec Ba-16-40 1 inch 18 kW
brazed plate heat exchanger with 40 plates and 1 inch
Plate Heat Exchanger NORDIC Ba-16-40 viessman 24kW

Plate Heat Exchanger NORDIC Ba-16-40 1" 150kW

40-Plate Brazed Heat Exchanger for central heating or DHW systems by NORDIC TEC Ba-16-40

Plate Q'ty: 40 pcs.
Connections: 1" BSP
Heat Exchange Area: 0.640m²

Reference: NT Ba-16-40
Condition New
Accessories for PHE
  • Exchanger only (without accesories)
  • with Wall-Mounting+Fittings
  • With Thermal Insulation
  • Full Set (with Insulation&Wall-mounting with Fittings)
On stock
€149.99
VAT included

 

Heat Exchanger 1" for central heating Nordic Tec Ba-16-40 - 4x 1", 40 plates


Technical details:

- Stainless Steel S316L, brazed with 99,9% Cu

- Connections: 4x 1", BSP

- Working Pressure - <20 bar

- Test Pressure - 40 bar

- Max. temperature +230°C

- Flowrate - 8 m³/h



- Heat Exchange Surface - 0.640 m²
Plate surface - fireplaces gas boilers heat exchanger Ba-16

Dimensions:

Dimensions of Ba-16-40 heat exchangers for domestic systems

Small FAQ - frequent questions from the Buyers:

_________________________

What is the weight of the Ba-16-40 plate heat exchanger?

The Ba-16-40 plate heat exchanger weighs approximately 2.8 kg, but if we plan installing it in our boiler room we should remember that it will be filled up with water. This means it can achieve the weight of cca. 4 kg.

What is the maximum flow rate of the Ba-16-40 plate heat exchanger?

The Ba-16-40 PHE can handle a maximum flow rate of 8 m³/h, but in fact when designing in order to not overcharge our circulation pumps - we should work with a flowrate of < 75% of the maximal capacity. Over this value the pressure ressistance grows up significantly. If we need something with a bigger flow capacities, but with relatively similar heat exchange area - we recommend the PHE Ba-32-20.

How often should the Ba-16-40 plate heat exchanger be serviced?

Recommendations about servicing a plate heat exchanger are in fact quite similar for every brand or producer - and they limit to more or less regular cleaning, which can make the life of the device much longer. It is recommended to clean our PHE at least once a year to ensure optimal longevity. This is the only maintenance of the unit, as well as checking for possible signs of wear. In fact not cleaned PHE units rarely get dommaged, but they work potentially less years than they could if there were services. We insist to not skip cleaning especially in older systems.